Evaluation of Dental Holder Innovation: Patient Comfort and Periapical Intra-Oral Radiographic Image Quality

Marichatul Jannah, Dimas Prakoso, Muhammad Erfansyah

Abstract


This study evaluates an innovative dental holder designed to improve patient comfort and radiographic image quality in intra-oral periapical examinations. Conducted at Muhammadiyah University Semarang Dental and Oral Hospital, the research involved 30 patients who used the modified holder featuring a 20-degree tilt, biocompatible PLA material, and silicone pads. Results showed that 73.33% of patients experienced no nausea, and 93.33% had no allergic reactions, highlighting the holder's safety and comfort. Although 56.67% reported excessive oral pressure, 60% noted reduced pain due to the silicone pads. The holder also improved image quality, with 76.67% of patients acknowledging clear apical images, and 100% reporting no distortion or blurring. The study indicates that while the holder significantly enhances patient comfort and image quality, further design adjustments are needed to address size-related issues. Future developments should focus on customizing the holder for local anatomical variations and exploring additional eco-friendly materials. Enhanced training for practitioners and further research with diverse populations are recommended to optimize the holder's effectiveness.

Keywords


Periapikal; Dental Holder; Patient Comfort; Image Quality

Full Text:

PDF

References


Balla, E., Daniilidis, V., Karlioti, G., Kalamas, T., Stefanidou, M., Bikiaris, N. D., Vlachopoulos, A., Koumentakou, I., & Bikiaris, D. N. (2021). Poly(lactic Acid): A Versatile Biobased Polymer for the Future with Multifunctional Properties—From Monomer Synthesis, Polymerization Techniques and Molecular Weight Increase to PLA Applications. Polymers 2021, Vol. 13, Page 1822, 13(11), 1822. https://doi.org/10.3390/POLYM13111822

Calero Castro, F. J., Padillo Eguía, A., Durán Muñoz-Cruzado, V., Tallón Aguilar, L., Tinoco González, J., Laga, I., de la Portilla de Juan, F., Pareja Ciuró, F., & Padillo Ruiz, J. (2023). Personalized additive manufacturing of devices for the management of enteroatmospheric fistulas. Bioengineering & Translational Medicine, 8(6), e10583. https://doi.org/10.1002/BTM2.10583

Chauhan, R. B., Shah, T. V., Shah, D. H., Gohil, T. J., Oza, A. D., Jajal, B., & Saxena, K. K. (2023). An overview of image processing for dental diagnosis. Https://Doi.Org/10.1142/S2737599423300015, 10. https://doi.org/10.1142/S2737599423300015

Connolly, M., Zhang, Y., Brown, D. M., Ortuño, N., Jordá-Beneyto, M., Stone, V., Fernandes, T. F., & Johnston, H. J. (2019). Novel polylactic acid (PLA)-organoclay nanocomposite bio-packaging for the cosmetic industry; migration studies and in vitro assessment of the dermal toxicity of migration extracts. Polymer Degradation and Stability, 168, 108938. https://doi.org/10.1016/J.POLYMDEGRADSTAB.2019.108938

Dong, H., Barr, A., Loomer, P., LaRoche, C., Young, E., & Rempel, D. (2006). The effects of periodontal instrument handle design on hand muscle load and pinch force. Journal of the American Dental Association, 137(8), 1123–1130. https://doi.org/10.14219/jada.archive.2006.0352

Elsawy, M. A., Kim, K. H., Park, J. W., & Deep, A. (2017). Hydrolytic degradation of polylactic acid (PLA) and its composites. Renewable and Sustainable Energy Reviews, 79, 1346–1352. https://doi.org/10.1016/J.RSER.2017.05.143

Frostell, A., Mattsson, P., & Svensson, M. (2018). Guiding device for precision grafting of peripheral nerves in complete thoracic spinal cord injury: Design and sizing for clinical trial. Frontiers in Neurology, 9(MAY), 340696. https://doi.org/10.3389/FNEUR.2018.00356/BIBTEX

Gigante, V., Coltelli, M. B., Vannozzi, A., Panariello, L., Fusco, A., Trombi, L., Donnarumma, G., Danti, S., & Lazzeri, A. (2019). Flat Die Extruded Biocompatible Poly(Lactic Acid) (PLA)/Poly(Butylene Succinate) (PBS) Based Films. Polymers 2019, Vol. 11, Page 1857, 11(11), 1857. https://doi.org/10.3390/POLYM11111857

Iannucci, J., & Howerton, L. J. (2016). Dental Radiography: A Workbook and Laboratory Manual.

Jannah, M., Engineering, R., Kemenkes Semarang, P., & Java, C. (2021). Innovation of Dental X-Ray Holder Using Silicone Rubber Coating in Posterior Dental Periapical Intraoral Examination. JURNAL INFO KESEHATAN, 19(1), 28–37. https://doi.org/10.31965/INFOKES.VOL19.ISS1.505

Jannah M, M. S. W. ;, G. P. (2023). Assessing Efficiency and Image Quality of Dental Radiography Using Modified Dental Holders with Silicone Rubber Integration. Jurnal Riset Kesehatan , 81–85.

Jensen, T. (1978). Improved reliability of dental radiography by application of x-ray beam-guiding instruments: a two-year report. Journal of Dental Education, 42(8), 481–485. https://doi.org/10.1002/J.0022-0337.1978.42.8.TB01203.X

Kesehatan, J. R., Jannah, M., Mulyati, S., Wingghayarie, ;, & Gandhi, P. (2023). Assessing Efficiency and Image Quality of Dental Radiography Using Modified Dental Holders with Silicone Rubber Integration. Jurnal Riset Kesehatan, 12(2), 81–85. https://doi.org/10.31983/JRK.V12I2.10484

Kwak, J. H., Lee, C. H., Kim, G. R., Lee, S. W., Kim, Y. H., Song, G. S., Son, D. W., Sung, H. C., Kwak, J. S., & Sung, S. K. (2021). Quality improvement of general anteroposterior radiographic image of vertebral body according to optimum angle of incidence. Journal of X-Ray Science and Technology, 29(2), 297–306. https://doi.org/10.3233/XST-200786

Naser, A. Z., Deiab, I., & Darras, B. M. (2021). Poly(lactic acid) (PLA) and polyhydroxyalkanoates (PHAs), green alternatives to petroleum-based plastics: a review. RSC Advances, 11(28), 17151–17196. https://doi.org/10.1039/D1RA02390J

Reynolds, T. (2016). Basic Guide to Dental Radiography (1st ed.). Wiley Blackwell.

Sanghvi, S., Rao, A., Karuna, Y. M., Shetty, K., & Nayak, A. (2018). Image distortion of the roots of maxillary deciduous molars on IOPA’s recorded with bisecting angle or a modified paralleling technique. Biomedical and Pharmacology Journal, 11(2), 1039–1042. https://doi.org/10.13005/BPJ/1464

Steffensen, C., Trypis, G., Mander, G. T. W., & Munn, Z. (2019). Effectiveness of adjusting radiographic technique parameters on image quality in direct digital radiography: a systematic review protocol. JBI Database of Systematic Reviews and Implementation Reports, 17(10), 2165–2173. https://doi.org/10.11124/JBISRIR-2017-003888

Teixeira, S., Morawa Eblagon, K., Miranda, F., Fernando, M., Pereira, R., Figueiredo, J. L., Morin, J.-F., & Savi, P. (2021). Towards Controlled Degradation of Poly(lactic) Acid in Technical Applications. C 2021, Vol. 7, Page 42, 7(2), 42. https://doi.org/10.3390/C7020042

Whaites, E., & Nicholas Drage. (2021). Essentials of Dental Radiography and Radiology, 6th Edition (6th ed.). Elsevier.

Yeung, A. W. K., & Wong, N. S. M. (2021). Reject Rates of Radiographic Images in Dentomaxillofacial Radiology: A Literature Review. International Journal of Environmental Research and Public Health 2021, Vol. 18, Page 8076, 18(15), 8076. https://doi.org/10.3390/IJERPH18158076




DOI: https://doi.org/10.31983/jrk.v13i2.12291

Article Metrics

Abstract view : 18
Download PDF : 7

Refbacks

  • There are currently no refbacks.




Copyright (c) 2024 Jurnal Riset Kesehatan

INDEXING

Logo Google Schoolar
Logo Sinta
Logo DOAJ
Logo Crossref
Logo Garuda
Logo Dimensions
RECOMMENDED TOOLS
Turnitin Logo
EndNote Logo
Mendeley Logo
Keep in touch with us!
Get notified
Logo Poltekkes Semarang Logo JRK
JURNAL
RISET
KESEHATAN

Mailing Address:

Jalan Tirto Agung, Pedalangan, Kec. Banyumanik, Kota Semarang, Jawa Tengah - 50268, Indonesia

Commitment to quality

Double-blind peer review. Immediate open access. Authors retain copyright. Author fee Rp 500.000,00. Published biannually.

 
CC Brands CC BY Brands CC SA Brands

Journal Riset Kesehatan (JRK), its website, and the articles published therein are licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.

WGA