INHOUSE TRAINING OPTIMISASI FAKTOR EKPOSI PEMERIKSAAN HSG GUNA MENDUKUNG PATIENT DAN RADIATION SAFETY DI RS ROEMANI

Siti Masrochah, RIni Indrati, Sri Mulyati

Abstract


Along with the development of technology various radiographic increasingly varied from a single exposure to the examination in serial. Including reproductive organs, one of which is known as Histerosalfingography examination (HSG) (Bontrager, 2000). Histerosalfingography is done by making a couple of times to get the radiation exposure according to the radiograph contrast media travel in the reproductive system. Therefore, patients also gain some exposure (exposure) radiation projection includes at least Antero posterior (AP), oblique, and lateral. On the other hand, the reproductive organs is one of the organs that are sensitive to radiation (Travis, 2000), it makes reality a dilemma, on one hand radiographs are required to get information anatomical features optimized to support diagnostic, on the other hand the sensitivity of organs high against radiation. Therefore, it is necessary election eksposi factors and appropriate treatment so that the negative effects of radiation does not occur in patients who do checks. It is necessary for the dissemination of research on the radiation dose received at each examination of the reproductive system (HSG) is. Thus, the method can be applied optimization Exposure factors in Histerosalfingography Examination for patient safety (patient safety) that need to be upheld in all health services.

Keywords


Optimisasi Faktor Eksposi, HSG, Keselamatan Radiasi dan Pasien

Full Text:

PDF

References


Akhadi, M. 2000. Dasar-dasar Proteksi Radiasi Cetakan Pertama). Rineka Cipta : Jakarta.

Ballinger, Philip W. dan Eugene D. Frank. 1999. Radiographic Positions & Radiologic Prosedures, Volume Two, Ninth Edition. Missouri : Mosby

Bontrager, Keneth L. 2001. Textbook of Radiographic Positioning and Related Anatomy. Missouri : Mosby

Bradshaw KD. 1998. Modern diagnostic evaluation and treatment algorithms for the infertile (eds): Textbook of Reproductive Medicine. 2nd edition. pp 533, 547 Norwalk, CT, Appleton-Lange.

Bryan, G. J.1979. Diagnostic Radiography, Eight Edition. Uffor limited. William Heinemann Medical Boch LTD. London

Mark C.Okeji, B.E. Udoh, N.O Chiaghanan. 2011. Evaluation of Absorbed dose during Hysterosalpingography in a Nigerian Hospital. European Journal of Scientific Research, Vol.67, pp 137-139

Masrochah, Siti. 2008. Analisis Entrance Skin Dose pada Pemeriksaan radiografi Thorax di BKPM Semarang

Progestian, Prima. 2010. Periksa Kesehatan Saluran Telur dengan HSG. http://www.ayahbunda.co.id/ Diakses tanggal 17 februari 2011 jam 17.45 WIB

Rasad, Sjahriar. 2006. Radiologi Diagnostik. Jakarta: FKUI.

R Kramer, H J Khoury, C Lopes and J.W Vieira. 2006. Equivalent dose to organs and tissues in hysterosalpingography calculated with the FAX (Female Adult voXel) Phantom.The British Journal of Radiology, Vol.79, pp 893-898

Travis, EL. Primer of Medical Radiobiology Year Book Medical Publisher, Chicago, USA, 1984.

Statkewicz, Mary, A. dkk. 2002. Radiation Protection In Medical Radiography. Mosby. Inc : Canada.

Swenson, Rand. 2009. Basic Human Anatomy. http://www.learnerhelp.com/ Diakses tanggal 27 februari 2011 jam 09.00 WIB

Sudiyono(2010), Analisis Dosis Radiasi yang diterima pasien pada pemeriksaan radiografi panoramic.

Verralls, Sylvia. 1997. Anatomi dan Fisiologi Terapan dalam Ilmu Kebidanan. Buku Kedokteran EGC : Jakarta.

Yoder, I.C.1988. Hysterosalpingography and Pelvis ultrasound imaging in Fertility and Gynecology. Little Brown and Company. Boston-Toronto.




DOI: https://doi.org/10.31983/link.v12i2.428

Article Metrics

Abstract view : 1203
Download PDF : 1197

Refbacks

  • There are currently no refbacks.


LINK (ISSN: 1829-5754 e-ISSN: 2461-1077), dipublikasikan oleh Pusat Penelitian dan Pengabdian kepada Masyarakat, Poltekkes Kemenkes Semarang, Jl. Tirto Agung, Pedalangan, Banyumanik, Semarang, Jawa Tengah 50268, Indonesia; Telp./Fax: (024)7460274

Public Services : 

 E-mail: link@poltekkes-smg.ac.id

View statistics

Creative Commons License LINK is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License