MEDICAL IMAGE COMPRESSION USING HYBRID METHOD OF SINGULAR VALUE DECOMPOSITION (SVD) AND DISCRETE WAVELET TRANSFORM (DWT) TO INCREASE ITS EFICIENCY OF SAVING AND TRANSMITION

Subinarto Subinarto, Edy Susanto, Nina Indriyawati

Abstract


This study aim was to increase the compression ratio and find out how much memory could be saved but also maintaining the quality of the image. The study was quantitative-analytic used samples of simple random sampling. Singular Value Decomposition algorithm (SVD) is a mathematical method to decipher a single matrix by compressing into three smaller matrices of the same size by reducing the data in columns and rows. while Discrete Wavelet Transform (DWT) is excellent in image energy concentrated on a small group of coefficients. It could also provide a combination of information about the frequency and scale resulting in a more accurate image reconstruction. Incorporation of these methods a compression system was lossy compression. The results of the compression process were carried out by compression rate calculation and MSSIM. The results of the study showed that compression system using a combination of SVD –DWT had a good performance. At Threshold_T = 15 and rank criteria _K = 4 generated the compression rate of 15.04% - 39.67%, or an average = 29.35% and MSSIM between 0.99 51,847 to 0.99 94 172 or average = 0.996219 with status almost close to 1, which mean the image of the original image compression and it could not be distinguished visual, it saved memory about 29.81%. It was better than DWT method tested in the same case with the result of the compression rate 28.85%.

Keywords


Medical images ; lossy compression ; Singular Value Decomposition (SVD) ; Discrete Wavelet Transform (DWT)

Full Text:

PDF

References


Mrs. S. Sridevi M.E, Dr.V.R.Vijayakuymar, Ms.R.Anuja. 2012. ”A Survey on Various Compression Methods for Medical Images”, I.J. Intelligent Systems and Applications, 3, 13-19

Digital Imaging and Communications in Medicine (DICOM), Part 17: Explanatory Information, Published by “National Electrical Manufacturers Association (NEMA)”, 1300 N. 17th Street, Rosslyn, Virginia 22209 USA

R.Bavithra, L.Ayeesha begame, K.S.L. Deepika. 2014. ”A Survey on Medical Image Compression Based on Transforms” SSRG International Journal of Electronics and Communication Engineering (SSRG-IJECE) – volume1 issue6 August

Rupinder Kaur, Nisha Kaushal. 2007. “Comparative Analysis of Various Compression Methods for Medical Images”, National Institute of Technical Teachers’ Training & Research, Panjab university, Chandigarh, Dept. of Computer Science & Engineering (CSE).

Gullanar M. Hadi. 2014. Medical Image Compression using DCT and DWT Techniques. Advances in Image and Video Processing, Volume 2 No 6, Dec ; pp: 25-35

Neha S. Korde, Dr. A. A. Gurjar. 2014. “Wavelet Based Medical Image Compression For Telemedicine Application” American Journal of Enginering Research (AJER), e-ISSN:2320-0847 p-ISSN:2320-0936. Volume-03. Issue-01. pp-106-111.

M. Antonini, M. Barlaud, P. Mathieu, and I. Daubchies. 1992. “Image coding using wavelet transform,” IEEE Trans. Image Process., vol. 1, no. 4, pp. 205–220, Apr.

Hoces, C. 1995. “Fractal compression theory”, IEEE Trans. Multimedia., vol. 2, no. 3, pp. 76–94, Apr.

Antonini, M. Barlaud, M. Mathieu, P. Daubechies, I. 1990. “Image coding using vector quantization in the wavelet transform domain”, International Conference on Acoustics, Speech & Signal Processing.

T. Sutoyo,S.Si, M.Kom, Edy Mulyanto, S.Si, M.Kom, Dr. Vincent Suhartono, Oky Dwi Nurhayati, MT, Wijanarto, M.Kom. 2009. “Teori Pengolahan Citra Digital”, diterbitkan atas kerjasama Penerbit Andi Yogyakarta dan Udinus Semarang.

Rehna. V. J , Jeyakumar. M. K. 2012. ”Singular Value Decomposition Based Image Coding for Achieving Additional Compression to JPEG Images”, International Journal of Image Processing and Vision Sciences (IJIPVS) Volume-1 Issue-1.

Adam Abrahamsen and David Richards. 2001. “Image Compression Using Singular Value Decomposition”, December 14,

Monika Rathee, Alka Vij. 2014. “Image compression Using Discrete Haar Wavelet Transforms”,International Journal of Engineering and Innovative Technology (IJEIT) Volume 3, Issue 12, June.

S. Sridhar. 2014. “Wavelet Transform Techniques for Image Compression – An Evaluation”, I.J. Image, Graphics and Signal Processing, 2, 54-67

M. Van Dijk, J. B. Martens. 1997. “Subjective Quality Assessment of Compressed Images”, Signal Processing, 58, 235-252.

M. Eskicioğlu. 1996. “Application of Multidimensional Quality Measures to Reconstructed Medical Images”, Opt. Eng. 35(3) 778-785 Mar.

M. Eskicioğlu, P. S. Fisher. 1995. “Image Quality Measures and Their Performance”, IEEE Trans. Commun., vol. 43, no. 12, December




DOI: https://doi.org/10.31983/link.v12i2.1386

Article Metrics

Abstract view : 744
Download PDF : 1304

Refbacks

  • There are currently no refbacks.


LINK (ISSN: 1829-5754 e-ISSN: 2461-1077), dipublikasikan oleh Pusat Penelitian dan Pengabdian kepada Masyarakat, Poltekkes Kemenkes Semarang, Jl. Tirto Agung, Pedalangan, Banyumanik, Semarang, Jawa Tengah 50268, Indonesia; Telp./Fax: (024)7460274

Public Services : 

 E-mail: link@poltekkes-smg.ac.id

View statistics

Creative Commons License LINK is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License