BENDEL KESLINGMAS NO 122TAHUN 2014
Abstract
This research is analytic research with cross sectional approach. Type of variable used is the free variable (disinfection), dependent variable (number of air germs), potentially confounding variables (temperature, humidity, lighting, ventilation and a vast volume of space).
According to the result of investigation, the average number of germs air before disinfection is 265 CFU/m3, after disinfection is 20 CFU/m3. Average effective disinfection is 92.45%. The average temperature was 23.5 oC. The average humidity was 50.55 %. The average lighting is 179.7 Lux. Extensive ventilation in Paviliun Soeparjo Rustam treatment room is 0.9 m2. Room volume is 36 m3.
Researchers concluded the use of disinfection is effective in reducing the number of air germs. The researcher gives suggestion if another researcher wants to do a disinfectant they must using full PPE.
Keywords
Full Text:
PDFReferences
Ayu Dwi Arini Putri, 2012, Studi Komparasi Angka Kuman Udara Sebelum dan Sesudah di Desinfeksi di Kamar Isolasi Ruang Dahlia RSUD Prof. Dr. Margono Soekarjo Purwokerto Tahun 2012, Purwokerto: Jurusan Kesehatan Lingkungan Purwokerto
Azrul Azwar, 1986, Pengantar Ilmu Kesehatan
Lingkungan, Jakarta: PT. Muria Sumber Widya
Bagian Monitoring dan Evaluasi, 2012, laporan Kinerja Bulanan, Purwokerto: RSUD Prof. Dr. Margono Soekarjo
DLL....
DOI: https://doi.org/10.31983/keslingmas.v33i122.3003
Article Metrics
Refbacks
- There are currently no refbacks.
Buletin Keslingmas (p-ISSN : 0215-742X, e-ISSN : 2655-8033 ), diterbitkan oleh Jurusan Kesehatan Lingkungan Politeknik Kesehatan Kemenkes Semarang Jl Raya Baturaden Km. 12 Purwokerto, Jawa Tengah, Indonesia. Telp/Fax. 0281-681709
Email : buletinkeslingmas@poltekkes-smg.ac.id
Buletin Keslingmas is licensed under a Creative Commons Attribution 4.0 International License