Introduction: Pelvic MRI examination in endometriosis cases does not theoretically use an ultrasonic gel that is inserted into the vagina and rectum, but also for sequences used without using the T1 sequence. Sagittal cut fat suppression. Radiology Installation Mayapada Hospital, South Jakarta for Pelvic MRI examination with Endometriosis cases using Gel and T1_SPIR sequences from these differences the authors are interested in exploring information about Pelvic MRI examination in Endometriosis cases at Radiology Installation Mayapada Hospital, South Jakarta with the aim of knowing the role of gel and sequencing of T1_SPIR Sagittal pieces.

Method: This type of research is qualitative research with a case study approach. The method of data collection is done by observation, in-depth interviews with radiographers, radiology specialists and sending doctors and documentation. Data analysis is done by an interactive model, then the data is presented in the form of the narrative text so that conclusions can be drawn.

Results: The results showed that Pelvic MRI examination using Ultrasonic Gel in Endometriosis Cases in Mayapada Hospital Radiology Installation in South Jakarta used ultrasonic gel in the 50cc and 150cc vaginal organs, the sequences used were: T2W_TSE, T2W_SPIR, T1_SPIR, T1W, T2_FFE on Sagittal snippets, T2W_TSE, T2W_SPAIR, T1W_SPIR on coronal chunks, T1W_TSE, T1W_TSE_SPIR, T2W_TSE on axial chunks and DWI_3b_RT SENSE on axial chunks and SSh_URETER. The reason for using ultrasonic gel on MRI examination in the Pelvis at the Mayapada Hospital Jakarta Radiology Installation is to see a clear difference between normal tissue and pathological tissue and expressly demarcate organ boundaries and play a role in widening the vaginal cavity and rectum. The reason for adding the sagittal cut T1_SPIR sequence in the case of Endometriosis at the Mayapada Hospital Radiology Installation in South Jakarta is to show lesions suspected of blood or other intensity and to ensure bleeding.

Keywords


MRI Pelvis; Ultrasonic Gel; Endometriosis; T1_SPIR_Sagital; Mayapada Hospital Jakarta Selatan

Full Text:

PDF

References


Blink, Ever J. 2004. MRI Physics for anyone who does not have a degree in physics. Germany.

Gupta, Sajal et al. 2015. Endometriosis A Comprehensive Update. Newyork:Springer.

Kay, Helen H and Charles E Spritzer. 2008. Magnetic Resonance Imaging in Gynecology. Durham:Glowm.

Mooler, Torsten B and Emil Reif. 2001.Pocket Atlas of Sectional Anatomy. New York:Thieme Stuttgart.

Mooler, Torsten B. 2003.MRI Parameters and Positioning.New York : Georg ThiemeVeriag.

Notosiswoyo, M dan SusySuswati. 2004. Pemanfaatan Magnetic Resonance Imaging (MRI) sebagaisaranadiagnosapasien. Media LitbangKedehatan Volume XIV Nomor 3.

Oliver and Siegelman. 2012. MR Imaging of Endometriosis:ten Imaging Pearls. Philadelphia:RSNA. Volume:32 number:6.

Paulsen, F dan J.Waschke. 2013. Sobotta atlas Anatomi Manusia. Jakarta:Kedokteran EGC. Edisi 23.

Ribeiro, M Margarid et al. 2013. STIR,SPIR and SPAIR Techniques in Magnetic Resonance of the breast. Portugal:J Biomedical Science and Engineering.

Sumiati. 2013. Sistem Reproduksi Manusia. Mataram:Jurnal Biologi. Volume 2 nomor 2.

Suparman, erna. 2012. Penatalaksaan Endometriosis. Manado:Jurnal Biomedik. Volume 4 nomor 2.

Suprijanto et al. 2009. Segmentasi Citra Secara Semi-Otomatis Untuk Visualisasi Volumetrik Citra CT-Scan Pelvis. Bandung:makara Teknologi. Volume 13 nomor 2.

“Ultrasonic Couplant Gel”. Company Registration Number 6976251.

Westbrook, Chaterine, Carolyne Kaut and John Talbot. 2011. MRI in Practice Fourth Edition. United Kingdom: Blackwell Publishing Ltd.

Westbrook, Chaterine. 2014. Handbook of MRI Technique Fourth Edition. United Kingdom:Wiley Blackwell Ltd.




DOI: https://doi.org/10.31983/jimed.v5i2.4474

Article Metrics

Abstract view : 1992
Download PDF : 1735

Refbacks

  • There are currently no refbacks.



Creative Commons License  Statcounter Global Stats - Browser, OS, Search Engine including Mobile  Usage Share          Dimensions AI | The most advanced scientific research database

             
JURNAL IMEJING DIAGNOSTIK by http://ejournal.poltekkes-smg.ac.id/ojs/index.php/jimed is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.

View My Stats