RADIATION DOSE ESTIMATION WITH CALDOSE_X VERSION 5.0 IN RADIOLOGICAL LABORATORY DEPARTMENT OF RADIODIAGNOSTIC AND RADIOTHERAPY TECHNIQUE

Agung Nugroho Setiawan

Abstract


Background: Media in the educational perspective is a strategic instrument in determining the success of the teaching and learning process. On radiographic examination, each patient is always at risk of exposure to ionizing radiation that is not necessary. Students need to learn whether the exposure factors which they use on patients is still below of the diagnostic reference level. This article purpose to get an overview of the radiation dose estimation using CALDose_X version 5.0 software as a laboratory-learning instrument in Radiological Laboratory Department of Radio diagnostic and Radiotherapy Technique, Poltekkes Kemenkes Semarang.

Methods: This article contains a description of using this software. The sample type is purposive sampling, which consist of seven types of radiographic examinations belong to The Head of Bapeten Regulation Number 8 of 2011. Entrance surface air kerma (ESAK) value from each exposure factors compared with Bapeten dose limit.

Results: The result showed this software able to calculate the incident air kerma of radiographic examination based on the output parameters of an X-ray tube. All of ESAK values confirm with the Bapeten dose limit.

Conclusion: The CALDose_X version 5.0 can be proposed as an instructional media to teach students in estimating absorbed dose to organs and tissues of the human body, the effective dose as well as the patient’s cancer risk for radiographic examinations.


Keywords


Radiation Dose, Instructional Media;CALDose_X;Bapeten Dose Limit

Full Text:

PDF

References


Arsyad, A. 1997. Media Pengajaran. 3 ed. Jakarta: Raja Grafindo Persada

Fazakerley, J, Ofori E, Scutt D, Ward M, Moores BM. 2016. Patient Dose Audit of Radiology Depatments Across Ghana. May:1–2.

ISRRT. 2018. World Radiography Day 2018. President’s Message. https://www.isrrt.org/blog/world-radiography-day-2018-president’s-message

Inyang SO, Essien IE, Antia AD. 2015. Entrance Surface Air Kerma for Chest X-ray Examination in some Diagnostic Radiologic Facilities in Akwa Ibom State , Nigeria. 48(9):4–8.

Kramer R, Khoury HJ, Vieira JW. 2010. CALDose _ X : a software for the calculation of absorbed dose to radiosensitive organs and for the assessment of radiological risks for patients submitted to X-ray radiography CALDose _ X : um software para calcular dose absorvida em órgãos radiossensívei, 4(2):

Moey, SF, Shazli ZA. 2018. Optimization of Dose and Image Quality in Full-field Digital and Computed Radiography Systems for Common Digital Radiographic Examinations. Iran J Med Phys, 15(February):28–38. http://ijmp.mums.ac.ir/article_9546_14a4845c6be4ffd83b1a2c4a21dc3d2f.pdf

Manuaba, IB. 2010. Pengukuran Entrance Surface Dose (ESD) pada Pemeriksaan Dada Computed Radiography (CR) dengan Beberapa Metoda Pengukuran. Universitas Indonesia

Sugiyono. 2001. Metode Penelitian Administrasi. Bandung: Alfabeta

Seeram, Euclid, Brennan, Patrick C. 2006. Diagnostic reference levels in radiology. http://www.entrepreneur.com/tradejournals/article/146630002_1.html.

Suliman II, Al-Jabri AJ, Badawi AA, Halato MA, Alzimami K, Sulieman A. 2014. Radiation dose and cancer risk in patients undergoing multiple radiographs in intravenous urography X-ray examinations. Radiat Phys Chem, November 104:272–5. http://linkinghub.elsevier.com/retrieve/pii/S0969806X13006658

Yacoob HY, Mohammed HA. 2017. Assessment of patients X-ray doses at three government hospitals in Duhok city lacking requirements of effective quality control. J Radiat Res Appl Sci, 10(3):183–7. http://linkinghub.elsevier.com/retrieve/pii/S1687850716300875




DOI: https://doi.org/10.31983/jimed.v5i1.3995

Article Metrics

Abstract view : 1159
Download PDF : 1610

Refbacks

  • There are currently no refbacks.



Creative Commons License  Statcounter Global Stats - Browser, OS, Search Engine including Mobile  Usage Share          Dimensions AI | The most advanced scientific research database

             
JURNAL IMEJING DIAGNOSTIK by http://ejournal.poltekkes-smg.ac.id/ojs/index.php/jimed is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.

View My Stats