Rancang Bangun Alat Bantu Fiksasi Pemeriksaan Radiografi Lumbal Oblik

Agustina Dwi Prastanti, Haris Sulistiyadi, Halinda Fatmayanti

Abstract


Background: The oblique lumbar examination has been carried out. The position of object isn't object angle at 45° to the image receptor, but only estimate it. It caused not optimal image of scottie dog sign and spondylolysis (pressure in pars interarticularis). Therefore, an examination aid is needed to make it easier to obtain the position of the oblique lumbar object.

Methods: This research design is a RnD study with the ADDIE model which is carried out with five stages, namely analysis, design, development, implementation, and evaluation. The data is carried out by observing, designing, testing, and analyzing whether there are artifacts.

Results: An oblique lumbar radiographic examination fixation aid was produced from acrylic material with a thickness of 5 mm. Acrylic is shaped like a right-angled triangular prism building which has a longer base measuring 50 cm, width 42 cm, and height 25 cm. A rectangular base with a length of 50 cm is pressed against the patient's body so that the supporting part of the angled triangle that supports the patient's lumbar region or the patient's body does not shift during an oblique lumbar radiography examination. This tool has a mass dimension of 2.5kg.

Conclusion: The design of the oblique lumbar radiographic examination fixation tool resembles a right-angled triangular prism with one side tilted at a 45 degree angle to adjust the position of the object so that it can obtain a good view of the Scottie dog sign to show part of the pars interarticularis.

Keywords


fixation tool; radiography; oblique lumbal; scottie dog

Full Text:

PDF

References


Baig, M., Byrne, F., Devitt, A., McCabe, J. P., Baig, M., Byrne, F., … McCabe, J. P. (2018). Signs of Nature in Spine Radiology. Cureus, 10(4). https://doi.org/10.7759/CUREUS.2456

Ballinger, P. W., Frank, E. D., & Merrill, V. (2003). Merril’s Atlas of Radiographic and Radiologic Procedures Volume One. Retrieved from https://books.google.com/books/about/Merrill_s_Atlas_of_Radiographic_Position.html?id=SCieyAEACAAJ

Edilla, J. Y. Z. (2017). Penentuan Suhu Optimal Proses Pembentukan Profil pada Mesin Vakum Akrilik. Jurnal Elektro Dan Mesin Terapan, 3(2), 1–10. https://doi.org/10.35143/elementer.v3i2.1523

Lampignano, J. P., & Kendrick, L. E. (2018). Textbook of Radiographic Positioning and Related Anatomy Ninth Edition.

Park, J. S., Moon, S. K., Jin, W., & Ryu, K. N. (2010). Unilateral lumbar spondylolysis on radiography and MRI: Emphasis on morphologic differences according to involved segment. American Journal of Roentgenology, 194(1), 207–215. https://doi.org/10.2214/AJR.09.2937

Santiago, F. R., Ramos-Bossini, A. J. L., Wáng, Y. X. J., & Zúñiga, D. L. (2020). The role of radiography in the study of spinal disorders. Quantitative Imaging in Medicine and Surgery, 10(12), 2322–2355. https://doi.org/10.21037/qims-20-1014

Syrmou, E, Tsitsopoulos, P. P., Marinopoulos, D., Tsonidis, C., Anagnostopoulos, I., & Tsitsopoulos, P. D. (2010). Spondylolysis: A review and reappraisal. Hippokratia, 14(1), 17–21.

Syrmou, Efstratia, Tsitsopoulos, P. P., Marinopoulos, D., Tsonidis, C., Anagnostopoulos, I., & Tsitsopoulos, P. D. (2010). Spondylolysis: A review and reappraisal. Hippokratia, 14(1), 17–21.




DOI: https://doi.org/10.31983/jimed.v10i1.11076

Article Metrics

Abstract view : 191
Download PDF : 143

Refbacks

  • There are currently no refbacks.



Creative Commons License  Statcounter Global Stats - Browser, OS, Search Engine including Mobile  Usage Share          Dimensions AI | The most advanced scientific research database

             
JURNAL IMEJING DIAGNOSTIK by http://ejournal.poltekkes-smg.ac.id/ojs/index.php/jimed is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.

View My Stats