Crossmatch to Transfusion Ratio (C/T Ratio) Komponen Darah WB dan PRC
Abstract
A crossmatch test between patient and donor’s blood must be carried out before blood transfusion. However, not all crossmatched blood will be transfused to the patient. This indicates inappropriate distribution of blood products, blood wastage, inaccessibility of blood for emergency patients, increased costs, and increased workload for staff. Crossmatch to Transfusion Ratio (C/T Ratio) is used as an indicator to determine the efficiency of blood use and can serve as a guide to anticipate excessive blood demand. This study aims to determine C/T Ratio score of blood components WB and PRC in the Brebes Regency Hospital 2021. This research is a descriptive study with a retrospective approach. Sampling was done using total sampling technique. Data was obtained from the blood requests recapitulation book in Brebes Regency Hospital’s Blood Bank 2021. The result showed there were 47 units WB crossmatched and 34 units (72%) transfused. There were 4589 units PRC crossmatched and 4369 units (95%) transfused. The C/T Ratio score of WB is 1.38. The C/T Ratio score of PRC is 1.05. The overall C/T Ratio score is 1.05.
Keywords
Full Text:
PDFReferences
Aggarwal, G., Tiwari, A., Arora, D., Dara, R., Acharya, D., Bhardwaj, G., & Sharma, J. (2018). Advantages of type and screen policy: Perspective from a developing country! Asian Journal of Transfusion Science, 12(1), 42. Diakses pada 17 April 2022 dari https://doi.org/10.4103/ajts.ajts_31_17
Bansal, K., & Kakkar, R. (2017). Study Of The Ratio Of Cross-Matching To Transfusion Of Blood Or Blood Component, I.E. Packed Red Blood Corpuscles To Develop Good Practices For The Utilisation Of Blood. Journal of Evolution of Medical and Dental Sciences, 6(35), 2909–2914. Diakses pada 7 September 2021 dari https://doi.org/10.14260/jemds/2017/627
Herlinah, Muhiddin, R., & Arif, M. (2016). Permintaan Darah Persiapan Tindakan Bedah di RSUP Dr. Wahidin Sudirohusodo. Indonesian Journal Of Clinical Pathology And Medical Laboratory, 22(2), 133–136. Diakses pada 30 Maret 2022 dari https://indonesianjournalofclinicalpathology.org/index.php/patologi/article/view/1115
Ismail, A., Karim, F. A., Iliassa, I. I., & Noordin, S. S. (2022). Factors Contributing to Red Blood Cells Crossmatch and Transfusion among Obstetrics Patients in a Single Tertiary Hospital. IIUM Medical Journal Malaysia, 21(1), 90–98. Diakses pada 31 Maret 2022 dari https://journals.iium.edu.my/kom/index.php/imjm/article/view/1992
Kementerian Kesehatan Republik Indonesia. (2015). Peraturan Menteri Kesehatan Nomor 91 Tahun 2015 Tentang Standar Pelayanan Transfusi Darah. Jakarta: Kementerian Kesehatan RI. Diakses pada 2 Oktober 2021 dari http://hukor.kemkes.go.id/uploads/produk_hukum/PMK_No._91_ttg_Standar_Transfusi_Pelayanan_Darah_.pdf
Lowe, E., & Quarmby, J. (2017). Are we cross-matching too much blood for elective open abdominal aortic aneurysm repair? SAGE Open Medicine, 5, 205031211668884. Diakses pada 7 September 2021 dari https://doi.org/10.1177/2050312116688843
Maharani, E. A., & Noviar, G. (2018). Bahan Ajar Teknologi Laboratorium Medik (TLM): Imunohematologi dan Bank Darah. Jakarta: Pusdiknakes SDM Kesehatan. Diakses pada 7 September 2021 dari http://bppsdmk.kemkes.go.id/pusdiksdmk/wp-content/uploads/2018/09/Imunohematologi-dan-Bank-Darah_SC.pdf
Muthuragavan, S., Hariharan, A., & Chitra, S. (2020). Comparison of Cross Match and Transfusion Ratio with Utilization of Blood Components. European Journal of Molecular & Clinical Medicine, 7(8), 3558–3560. Diakses pada 7 September 2021 dari https://ejmcm.com/article_6298.html
Tesić, I., Velisavljev, D., & Martinov, D. (2013). The type and screen method of blood requisition in General Hospital Zrenjanin. Medicinski Pregled, 66(1–2), 58–63. Diakses pada 18 April 2022 dari https://doi.org/10.2298/mpns1302058t
Triyono, T., & Anshori, F. (2019). Analisis Crossmatch To Transfusion Ratio (CTR) dalam Implementasi Standar Akreditasi Pelayanan Darah di Rumah Sakit. Yogyakarta: UTD RSUP Dr. Sardjito. Diakses pada 7 September 2021 dari https://docplayer.info/213133711-Analisis-crossmatch-to-transfusion-ratio-ctr-dalam-implementasi-standar-akreditasi-pelayanan-darah-di-rumah-sakit.html
Yasmeen, I., Ahmed, I., & Bashir, S. (2021). Efficiency of blood utilization and characteristics of patients receiving blood transfusion at an associated hospital in North India. International Journal of Research in Medical Sciences, 9(4), 1056. Diakses pada 28 Januari 2022 dari https://doi.org/10.18203/2320-6012.ijrms20211350
Yazdi, A. P., Alipour, M., Jahanbakhsh, S. S., Gharavifard, M., & Gilani, M. T. (2016). A Survey of Blood Request Versus Blood Utilization at a University Hospital in Iran. The Archives Of Bone And Joint Surgery, 4(1), 75–79. Diakses pada 7 September 2021 dari https://pubmed.ncbi.nlm.nih.gov/26894224/
Yolanda, F. A. (2017). Analisis Efisiensi Penggunaan Labu Darah Dalam Tindakan Operasi di RSUP Fatmawati Tahun 2017, Skripsi, Universitas Indonesia. Diakses pada 3 Januari 2022 dari https://lib.ui.ac.id/detail?id=20458616&lokasi=lokal
Zewdie, K., Genetu, A., Mekonnen, Y., Worku, T., Sahlu, A., & Gulilalt, D. (2019). Efficiency of blood utilization in elective surgical patients. BMC Health Services Research, 19(1). Diakses pada 7 September 2021 dari https://doi.org/10.1186/s12913-019-4584-1
DOI: https://doi.org/10.31983/jlm.v5i1.8587
Article Metrics
Refbacks
- There are currently no refbacks.
Copyright (c) 2023 Jaringan Laboratorium Medis
This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.
--
OFFICE INFORMATION :
Jurusan Analis Kesehatan - Kemenkes Poltekkes Semarang, https://analis.poltekkes-smg.ac.id Jl. Wolter Monginsidi No. 115 Pedurungan Tengah, Semarang, Jawa Tengah, Indonesia ; Telp./Fax: (024)6723014 Email: jlm@poltekkes-smg.ac.id
Jaringan Laboratorium Medis disseminated below Creative Commons Attribution-ShareAlike 4.0 International License.
Our Related Accounts :
MoU PATELKI | ISSN BRIN | Google Scholar | Garuda | Stat Counter | DOI Crossref |
Jaringan Laboratorium Medis © 2019 |