ANALYSIS OF WINDOW WIDTH VARIATION ON IMAGE ANATOMICAL INFORMATION MSCT STONOGRAPHY

Muhammad Izzudin, Gatot Murti Wibowo, Mohamad Hidayatullah

Abstract


Multi Slice Computed Tomography is a diagnostic imaging method that can display cross section anatomy in the axial, sagital, and coronal areas. MSCT Stonography imaging both visualizes the anatomy of the urinary tract and stone pathology supported by the presence of ureter tracking techniques and without using contrast media. On this method, the appropriate window width will produce an optimal anatomical picture. The Study aims to determine the effect of window width on anatomical image information on MSCT Stonography.

Type of research is quantitative experimental approach, conducted in January-February 2020 in Hasan Sadikin Bandung hospital, Bandung. Research with variations  in window width 300 HU, 350 HU, 400 HU, 450 HU, and 500 HU on MSCT stonography og 10 patients. Criteria’s patients is patients with clinical kidney stones, willing to be a research sample. Result imagery rated two respondents, include parenchymal kidney, pelvic calices kidney, ureters, vesica urinary, and stones kidney. Then do Kappa test continued testing Friedman to know the highest mean rank and the influence og the window width oh the image og MSCT stonography.

Based on the result of the Friedman statistical test overall anatomy obtained significance value (p-value) = 0.000 < 0.05 means that there is an influence of window width value, the contrast resolution will increase and the better the firm boundary, but the resulting image will be more radioluscent. Based on Friedman’s mean rank test result obtained the highest mean rank of 3,54 in a variation of window width 300. The most optical window displays anatomy information using window width 300.

 

Keyword : window width, MSCT stonography


Full Text:

PDF

References


Bontrager, K.L., Lampignano, J.P. 2018. Bontrager’s Textbook of Positioning and Related Anatomy. Seventh Edition. CV. Mosby Company, St. Louis.

Bushberg, J. T. 2012. The Essential Phisics of Medical Imaging. Third Edition. Lippincot Williams & Wilkins. Philadelphia.

Bushong, C.S. 2017. Radiologic Science For Technologist. Tenth Edition.

Elsevier Mosby. St. Louis.

Andersson, T., Mathias Broxvall., Liden Matz., Per Thunberg., Hakan Geijer. 2012, Urinary Stone Size Estimation : A New Segemntation Algorithma Based CT Method. Uropean Journal of Radiology.

Yasir, a., Patino M., Kambadakone Avinash. 2015, Advances in CT imaging for urolithiasis. Uropean Journal of Radiology.

Romain, G., Benoit S., Matias G., Daudon M. 2010, Charecterization of Human renal Stones with MDCT : Advantage of DualEnergy and Limitations Due to Respiratory Motion. Uropean Journal of Radiology.

Hamimi, A., El Azab, M. 2015. MSCT Renal Stone Protocol; Dose Penalty and Influence on management decision of patiens: Is it really worth the radiation dose?

Joffe, S.A, MD, Servaes, S, MD, Okon, S, MD, Horowitz, M, MD. 2003. Multi- Detector Row CT Urography in the Evaluation of Hematuria1.

Lampignano, J.P., Kendrick, L.E. 2018. Bontrager’s Textbook Radiographic Positioning and Related Anatomy. Ninth Edition. Elsevier. St. Louis.

Long, B.W., Rollins J.H., Smith, B.J. 2016. Merril’s Atlas of Radiographic Positioning & Procesdures Volume Three. Thirteenth Edition. Elsevier Mosby. 3251 Riverpoort Lane St Louis, Missouri,63043.

Lubis Abdurrahim, Rasyid Lubis. 2012. Divisi Nefrologi dan Hipertensi, Departemen Ilmu Penyakit Dalam. FK- USU/RSUP H. Adam Malik. Medan.

Pranoto, Yuni Eko 2017. Teknik Tracking Ureter MSCT Urografi Polos Pada Psien Dengan Kadar Ureum dan Kreatinin Tinggi di Instalasi Radiologi RS Islam Jakarta Cempaka Putih. Prodi D-IV Teknik Radiologi, Jurusan Teknik Radiodiagnostik. Politeknik Kesehatan Semarang. Semarang.

Faslikha, Gandha Rizki 2018. Prosedur Pemeriksaan MSCT Urografi dengan Klinis Kolik Renal di Instalasi Radiologi RS Islam Jakarta Cempaka Putih. Prodi D-IV Teknik Radiologi, Jurusan Teknik Radiodiagnostik. Politeknik Kesehatan Semarang. Semarang.

Medical, Siemens. 2018. Computed Tomography : Its History and Technology. Siemens Medical Solution. Germany. http://globaldxi.com/featureddocs/CT_History_and_Technology.pdf Diakses tanggal 2 Januari 2020.

Mehmed, M.M., & Ender O., (2015). Effect of urinary stone disease and it’s treatmen on renal function.World J Nephro: 4(2):271-276l.

Niemann, T., Straten V., Resinger C., Bayer T., Bongartz G. 2010, Detection of Urolithiasis Using Low-Dose Simulation Study. Uropean Journal of Radiology.

Purnomo B. 2016. Dasar-dasar Urologi. Sagung Seto. Jakarta.

Shaaban, M.S, Kotb, A.F. 2015. Value Of Non Contrast CT Examination Of The Urinary Tract (Stone Protocol) In The Detection Of Incidental Findings And Its Impact Upon The Management.

Seeram, E. 2018. Computed Tomography : physical principles, clinical applications, and quality control. Third edition. WB Saunders Company, Philadelphia.

Sherwood, Lauralee. 2012. Fisiologi manusia dari sel ke sel (human Physiology: From Cells to System). Edisi 6. Departement of Physiology and Pharmacology School of Medicine West Virginis Univesity. EGC. Jakarta.

Sloane, Ethel. 2016. Anatomi dan Fisiologi untuk pemula / Ethel Sloane ; alih bahasa, James Veldman ; editor edisi bahasa indonesia ,Palupi Widyastuti,Jakarta: EGC.

Sulaksono, Nanang., Ardiyanto, Jeffri. 2016. Optimalisasi Citra MSCT Traktus Urinarius menggunakan Tracking dengan Variasi Slice Thickness dan Window Setting. Prodi D-IV Teknik Radiologi, Jurusan Teknik Radiodiagnostik dan Radioterapi, Politeknik Kesehatan Semarang. Semarang.

Wayne, W. Daniel. 2005. BIOSTATISTICS ; A Foundation for Analysis in the Health Sciences. Eight Edition. John Wiley & Sons, Inc




DOI: https://doi.org/10.31983/jahmt.v1i2.6855

Article Metrics

Abstract view : 249
Download PDF : 171

Refbacks

  • There are currently no refbacks.


Journal of Applied Health Management and Technology (p-ISSN: 2715-3061  e-ISSN: 2715-307X , Postgraduate Program, Poltekkes Kemenkes Semarang.