DEVELOPMENT OF TOOLS OF THE X-RAY COLLIMATOR (DEV-X)

I Made Lana Prasetya, Hari Santoso, Gatot Murti Wibowo

Abstract


Background: Technological developments, especially in the field of radiology, is growing rapidly. The radiology quality assurance system has also developed, one of which is the Collimator Test Tools. The method of testing x-ray beams using this tool has also been developed, such as using film and using IP. However, the development of this method has a drawback, namely that the examiner is required to have special skills in image post-processing. The development of Collimator Test Tools by utilizing the nature of x-rays which causes certain substances such as calcium tungstate or zinc sulfide to glow light (luminance) has been done a lot, but there is no study of these products. Therefore, the researcher wants to develop a product by designing a Collimator test tool based on digital image analysis technology (Dev-X) and a digital camera with Android-based calculations on a wirelessly connected smartphone as an update of the testing method. Objective: To create a collimator test tool for x-ray machines based on digital image analysis technology (Dev-X). Methods: This is a research experiment with a posttest group only design type. Research Location at the Radiology Laboratory of the Radiodiagnostic and Radiotherapy Engineering Academy (ATRO) Bali. Result: Functional Test of Dev-X Products (hardware and software), all components function properly. However, it cannot be assessed significantly from statistical results. Conclusion: The creation and proper functioning of hardware and software tools collimator test tool Dev-Xon android smartphone and show the calculation results of the x-ray beam automatically.    


Keywords


Keywords: Quality Control, Collimator Test Tools, Digital Image Processing

Full Text:

PDF

References


Gatot M. Wibowo R, Sulistiyadi AH, Jurusan. Implementation of Compliance Testing Program on a Direct Digital Radiography ( DDR ) X-Ray System at the Radiography and Imaging Laboratory of the Health Polytechnic Ministry of Health Semarang Penerapan Program Uji Kesesuaian Pada Peralatan Sinar-X Direc. 2014;10(2):792-800.

Keputusan Mentri Kesehatan KMK no 1250. Tentang Pedoman Kendali Mutu (Quality Control) Peralatan Radiodiagnostik. 2009.

BAPETEN. Uji Kesesuaian Pesawat Sinar-X Radiologi Diagnostik Dan Intervensionali.; 2018.

Technology R. Collimator and Beam Alignment QC Tools Gammex Model 161B. 2015;31(0).

Meechai T, Chousangsuntorn K, Owasirikul W, Mongkolsuk M, Iampa W. Comparison of testing of collimator and beam alignment , focal spot size with slit camera , and tube current consistency using computed radiography and conventional screen ‐ film systems. 2019;(March):160-169. doi:10.1002/acm2.12600

RTI. Nova An X-ray/Light Field/Digital Image Alignment tool. J Chem Inf Model. 2013;53(9):1689-1699. doi:10.1017/CBO9781107415324.004




DOI: https://doi.org/10.31983/jahmt.v2i4.6386

Article Metrics

Abstract view : 408
Download PDF : 229

Refbacks

  • There are currently no refbacks.


Journal of Applied Health Management and Technology (p-ISSN: 2715-3061  e-ISSN: 2715-307X , Postgraduate Program, Poltekkes Kemenkes Semarang.
St. Tirto Agung, Pedalangan, Banyumanik, Semarang City, Central Java, Indonesia, Postal code 50268 Telp./Fax: (024)76479189

https://jurnal.usk.ac.id/lib/pkp/gacor4d/https://htn.parahikma.ac.id/sbotop/https://jurnal.usk.ac.id/lib/pkp/slotraffi/https://kemahasiswaan.mercubaktijaya.ac.id/sistem/