Faktor Eksposi terhadap Kualitas Citra Radiografi dan Dosis Pasien Menggunakan Parameter Penilaian Signal to Noise Ratio (SNR) pada Pemeriksaan Thorax Posteroanterior dengan Menggunakan Pesawat Computed Radiografi
Abstract
Background: The research was analyzing digital image quality and estimation dose patient by using Signal to Noise Ratio (SNR) on Computed Radiography. SNR can be used for analyzing digital image spatial resolution and estimation dose accurately. The aims of this study to determine the influence of exposure factors on image quality and estimation dose patient.
Methods: This type of research is a quantitative method with an experimental study. Direct experiments in August 2020 assessment with a sample of 9 adults posteroanterior chest photo with the average age of 20-50 years old with an average body weight of 50-69 kilograms.
Results: The measurement results showed that the digital images will be analyzed by SNR, so it can be determined the optimum exposed factor of the highest SNR value and dose radiation. From the analysis, the highest SNR value at 121 kV, current 1 mAs, the lower dose radiation at 121 kV, current 0,9 mAs.
Conclusions: There was an influence variation of an exposed factor on the quality of the image and dose to the patient.
Keywords
Full Text:
PDFReferences
Ackom, D., Inkoom, S., Sosu, E., & Schandorf, C. (2017). Assessment of Image Quality and Radiation Dose to Adult Patients undergoing Computed Radiography Examinations. International Journal of Scientific Research in Science and Technology, 3(8), 89–94. https://doi.org/10.32628/IJSRST173825
Ball, J. L., Price, T., & Moore, A. D. (1995). Chesneys’ Radiographic Imaging (6th ed.). Blackwell Science.
Bequet, A. Y., Rusyadi, L., & Fatimah, F. (2020). Nilai Contrast to Noise Ratio (CNR) Radiograf Thorax PA antara menggunakan Grid dengan tanpa Menggunakan Grid. Jurnal Imejing Diagnostik (JImeD), 6(2), 60–64. https://doi.org/10.31983/jimed.v6i2.5653
Bushong, S. C. (2013). Radiologic Science for Technologist : Physics, Biology, and Protection.
Carlton, R. R., & Adler, A. M. (2001). Principles of Radiographic Imaging An Art and Science 3rd Edition (Third Edition).
Daryati, S., Indrati, R., & Illahi, N. W. (2019). Description of Serap Dosagein Examination of Children Thorax Radiograph in Pulmonary Hospital Radiology Installation, Dr. Ario Wirawan Salatiga. Jurnal Imejing Diagnostik (JImeD), 5(1), 31. https://doi.org/10.31983/jimed.v5i1.4004
Hastuti, T. P., Kartikasari, Y., Abimanyu, B., & Sulaksono, N. (2020). Analisis Informasi Citra Anatomi MSCT Thorax dengan Kasus Efusi Pleura Kanker Paru pada Window Mediastinum Post Kontras menggunakan Variasi Nilai Window Width. Jurnal Imejing Diagnostik (JImeD), 6(1), 28–35. https://doi.org/10.31983/jimed.v6i1.5562
Rasad, S. (2018). Radiologi Diagnostik (2nd ed.). FKUI.
Uffmann, M., & Schaefer-Prokop, C. (2009). Digital Radiography: the balance between image quality and required radiation dose. European Journal of Radiology, 72(2), 202–208. https://doi.org/10.1016/j.ejrad.2009.05.060
Utami, A. P., Saputro, S. D., & Felayani, F. (2014). Radiologi Dasar I. Inti Medika Pustaka.
DOI: https://doi.org/10.31983/jimed.v7i1.6650
Article Metrics
Refbacks
- There are currently no refbacks.
JURNAL IMEJING DIAGNOSTIK by http://ejournal.poltekkes-smg.ac.id/ojs/index.php/jimed is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.