THE OPTIMIZATION OF MSCT OF URINARY TRACT USING TRACKING WITH FILTERS VARIATION

Nanang Sulaksono, Agustina Dwi Prastanti, Vederica Farida Candra

Abstract


Backgroud: Kidney disease is a clinical situation which is indicated by the decreasing of kidney functions and MSCT is one of the modalities to diagnose that function. Aim to identify the differences in image information with filter variation abdomen medium smooth and  Mediastinum Standard.

Methods: The method was the experimental research using research planning Post Test Only Group Design. The sampling was chosen consecutively. There were 3 Radiolog and  32 citra on the examination of MSCT abdomen without positive contrast media in Salatiga Public Hospital.

Results :The intervention validity experiment after a tracking filter with variations, kruskal Wallis test results. There are meaningful differences shows vlue of p value 0,000 (p<0,05), so that continued analysis of the Mann Whitney. The results of the analysis of the Mann Whitney pointed out that there is a difference between real or significant group of filter Medium Smooth Abdomen with Abdominal filter Medium Sharp/Mediastinum Standard Sig<0.05 p value 0.000).

Conclusion: a variation of the filter is able to identify the existence of a difference image information tracktus optimal unirarius MSCT abdomen after tracking by using the best filtr Medium Sharp Abdomen/Mediastinum Standard.


Keywords


MSCT;Tracking;Filters

Full Text:

PDF

References


European, C. 2000. European guidelines on quality criteria for computed tomography. Luxembourg. EUR 16262.

Florh T., Bruening R., dan Kuettner A.. 2006. Protocol for Multislice CT. Germany. Hal 213, 215.

Lin, C.W. 2004. Assessment of CT Urography in the Diagnosis of Urinary Tract Abnormalities. Journal of the Chinese Medical Association. Vol. 67, No. 2.

Sulaksono N, Suryono, Jeffri Ardiyanto. 2016. Optimalisasi Citra MSCT Traktus Urinarius Menggunakan Tracking dengan Variasi Slice Thickness dan Window Seting. Jurnal Riset Berkala.

Niemann T., Straten V., Resinger C., Bayer T., dan Bongartz G. 2010. Detection of Urolithiasis Using Low-Dose Simulation Study. Uropean Journal of Radiologi.

O’Connor A. 2007. Pathology. Mosby.

Pernefri. 2012. Konsensus Dialisis. Edisi I. Jakarta : Perhimpunan Nefrologi Indonesia FK UI.




DOI: https://doi.org/10.31983/jimed.v5i1.4011

Article Metrics

Abstract view : 654
Download PDF : 471

Refbacks

  • There are currently no refbacks.



Creative Commons License  Statcounter Global Stats - Browser, OS, Search Engine including Mobile  Usage Share          Dimensions AI | The most advanced scientific research database

             
JURNAL IMEJING DIAGNOSTIK by http://ejournal.poltekkes-smg.ac.id/ojs/index.php/jimed is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.