Pengembangan Model Aplikasi Pelatihan Pengendalian Mutu Computed Tomography (CT) Berbasis American College of Radiology (ACR) Phantom Terintegrasi Web

Authors

  • Rudy Harnanto Poltekkes Kemenkes Semarang
  • Kusworo Adi Poltekkes Kemenkes Semarang
  • Dartini Dartini Poltekkes Kemenkes Semarang
  • Gatot Murti Wibowo Poltekkes Kemenkes Semarang
  • Rasyid Rasyid Poltekkes Kemenkes Semarang

DOI:

https://doi.org/10.31983/jimed.v11i2.13457

Keywords:

ACR Phantom, CT quality control, web application, DICOM, PACS

Abstract

Background: The use of Viewdex as a tool for radiographic image evaluation has limitations in flexibility for students, particularly in the installation and input of DICOM ACR image results, which can be complex. This study aims to: (1) Evaluate the performance of the CT Scan training application for the Applied Bachelor Program in Radiologic Imaging Technology at Poltekkes Kemenkes Semarang, based on ViewDex; (2) Develop a web-integrated CT Scan quality control training application based on the ACR Phantom; (3) Measure the performance of the web-integrated CT Scan quality control training application based on the ACR Phantom.

Methods: The research method used is Research and Development (R&D), which includes literature study, product development, field testing, evaluation, and product revision. The developed application simplifies the process of importing DICOM data, coding questions, and automatic evaluation, thus improving operational efficiency.

Results: Validation by IT and QA/QC experts shows that the application meets high standards with 100% validity. Blackbox testing, which includes general functionality, security, compatibility, performance, usability, dashboard, and user interface, showed that the application is valid and operates well without significant errors. Performance evaluation through pre-test and post-test indicated a significant improvement in participants' knowledge and skills, with the Wilcoxon test yielding a p-value of 0.005, indicating a significant difference between conditions before and after using the application.

Conclusions: in conclusion, the developed application is effective and efficient in enhancing student usability and learning experience, overcoming the limitations of Viewdex. This application enables efficient management and analysis of medical images and data, making it well-prepared to support CT quality control training with high-quality standards.

References

Bushberg, J. T. (2012). The Essential Physics of Medical Imaging, Second Edition. Liippincott Williams & Wilkins.

Cantatore, A., & Müller, P. (2011). Introduction to computed tomography.

Dyah. (2018). Metode Penelitian Pendidikan Matematika. In Metode Penelitian Pendidikan Matematika.

Manual, Q. C. (2015). Magnetic Resonance Imaging Radiologist ’ s Section.

Menteri Kesehatan Republik Indonesia. (2008).

Middleton, W. (2017). ACR Acreditation Program/Testing Instruction.

Satzinger, J. W., Jackson, R. B., & Burd, S. D. (2012). S I X T H E D I T I O N Systems Analysis and Design I N a C H a N G I N G W O R L D.

Soekidjo Notoatmodjo. (2018). Pdf-Metodologi-Penelitian-Kesehatan-Notoatmodjo_Compress.Pdf.

Sturm, R., Pollard, C., & Craig, J. (2017). Managing Web-Based Applications. Application Performance Management (APM) in the Digital Enterprise, 83–93. https://doi.org/10.1016/B978-0-12-804018-8.00007-3

Suryawinata, O. M. (2019). Buku Ajar Mata Kuliah Pengembangan Aplikasi Berbasis Web Diterbitkan oleh UMSIDA PRESS.

Wibowo, G. M., Fahkruddin, F., Rustono, R., & Khafid, M. (2022). Training Evaluation Management Model of CT and MRI Quality Control Based on The ACR Phantom Using View Dex Administrator. 1294–1301.

Downloads

Published

2025-07-31

Issue

Section

Articles