Nilai Entrance Skin Dose Tiroid antara menggunakan Thyroid Shield dan tanpa Thyroid Shield pada Pemeriksaan CT Scan Kepala

Angga Yosainto Bequet, Panji Wibowo Nurcahyo, Susi Tri Isnoviasih

Abstract


Background: CT scans have a much greater dose than conventional radiographic examinations. The thyroid organ is an organ that is sensitive to radiation which is located near the head, precisely in the inferior part of the head so that when a CT scan of the head is carried out, the thyroid organ will be exposed to radiation. The aim of this study was to determine the difference in thyroid skin dose entry value between using a thyroid shield and without a thyroid shield on a head CT scan.

Methods: This study is a type of quantitative research with a pre-experimental design. The object of research is Entrance Skin Dose (ESE) of ThyroidOrgan on non-contrast head CT Scan examination. The research location is at the Radiology Department at the Regional General Hospital Prof. Dr. Margono Soekarjo Purwokerto. Sample data number is 50 people (25 samples of non-contrast head CT scans without thyroid shield, and 25 samples of non-contrast head CT scans with thyroid shield. Data was obtained by measuring the radiation dose using a dosimeter placed over the thyroid area during a non-contrast CT scan between using a thyroid shield and without using a thyroid shield. Data analysis was performed using statistical tests 

Results: The results of measuring the radiation dose to the samples showed that the average radiation dose to the skin surface of the thyroid organ on a non-contrast CT scan without using a thoracic shield was 884.96 µSv and using a thyroid shield was 428.64 µSv. This shows that the average radiation dose from the skin surface of the thyroid organ decreased by 456.32 µSv (51.56%).

Conclusions: There is a significant difference in the amount of radiation dose to the surface of the skin of the thyroid organ in non-contrast head CT scans between using a thyroid shield and without using a shield with a dose reduction of 51.6% of the radiation dose without using a thyroid shield.



Keywords


Head CT Scan; Thyroid Radiation Dose; Radiation Protection; Thyroid Shield; Entrance Skin Dose

Full Text:

PDF

References


Alkhateeb, S. M., Bamusa, A., Almutairi, N., Barayan, B., Alamodi, H., Alnadawi, F., & Alnowaimi, M. (2023). Effectiveness of protective thyroid shield in chest X-ray imaging. Radiation Physics and Chemistry (Oxford, England : 1993), 209, 110965. https://doi.org/10.1016/j.radphyschem.2023.110965

Bangsaku, S. N. S. (2022). Tingkatan Kualitas dan Layanan Stroke Lewat Transformasi Kesehatan. Kemenkes RI. https://sehatnegeriku.kemkes.go.id/baca/rilis-media/20221011/4641254/tingkatan-kualitas-dan-layanan-stroke-lewat-transformasi-kesehatan/

BKPK, H. (2022). Transformasi Kesehatan Sukseskan Tujuan Pembangunan Kualitas Hidup Masyarakat. Badan Kebijakan Pembangunan Kesehatan. https://www.badankebijakan.kemkes.go.id/transformasi-kesehatan-sukseskan-tujuan-pembangunan-kualitas-hidup-masyarakat/

Bontrager, K. L., & Lampignano, J. P. (2014). Textbook of Radiographic Positioning and Related Anatomy (8th ed.). Elsevier Mosby.

Carver, E., & Carver, B. (2012). Medical Imaging: Technique, Reflection & Evaluation (2nd ed.). Churchill Livingstone, Elsevier.

Cheon, B. K., Kim, C. L., Kim, K. R., Kang, M. H., Lim, J. A., Woo, N. S., Rhee, K. Y., Kim, H. K., & Kim, J. H. (2018). Radiation safety: a focus on lead aprons and thyroid shields in interventional pain management. The Korean Journal of Pain, 31(4), 244–252. https://doi.org/10.3344/kjp.2018.31.4.244

Hiswara, E., & Kartikasari, D. (2015). Dosis Pasien Pada Pemeriksaan Rutin Sinar-X Radiologi Diagnostik. Jurnal Sains Dan Teknologi Nuklir Indonesia, 16(2). https://doi.org/DOI: http://dx.doi.org/10.17146/jstni.2015.16.2.2359

McCollough, C. H., Primak, A. N., Braun, N., Kofler, J., Yu, L., & Christner, J. (2009). Strategies for reducing radiation dose in CT. Radiologic Clinics of North America, 47(1), 27–40. https://doi.org/10.1016/j.rcl.2008.10.006

Osman, H., Raafat, B. M., Faizo, N. L., Ahmed, R. M., Alamri, S., Alghamdi, A. J., Almahwasi, A., Alharbi, M. K. M., Sulieman, A., & Khandaker, M. U. (2021). Exposure levels of CT and conventional X-ray procedures for radiosensitive pelvic organ in Saudi Arabia. Journal of Radiation Research and Applied Sciences, 14(1), 449–455. https://doi.org/https://doi.org/10.1080/16878507.2021.2002005

Seeram, E. (2016). Computed Tomography: Physical Principles, Clinical Application, and Quality Control (4th ed.). Elsevier.

Tipnis, S. V, Spampinato, M. V, Hungerford, J., & Huda, W. (2015). Thyroid Doses and Risks to Adult Patients Undergoing Neck CT Examinations. AJR. American Journal of Roentgenology, 204(5), 1064–1068. https://doi.org/10.2214/AJR.14.13102




DOI: https://doi.org/10.31983/jimed.v10i1.10816

Article Metrics

Abstract view : 60
Download PDF : 39

Refbacks

  • There are currently no refbacks.



Creative Commons License  Statcounter Global Stats - Browser, OS, Search Engine including Mobile  Usage Share          Dimensions AI | The most advanced scientific research database

             
JURNAL IMEJING DIAGNOSTIK by http://ejournal.poltekkes-smg.ac.id/ojs/index.php/jimed is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.

View My Stats