Blood is an important fluid in the body that functions to circulate nutrients, carry metabolic waste, and play a role in the body's defense system. Leukocytes, especially neutrophils and lymphocytes, are white blood cells that play a major role in the immune response. One of the hematology tests often performed to assess the morphology and percentage of leukocytes is the examination of peripheral blood smears with Giemsa staining. The quality of Giemsa staining results is influenced by the pH of the phosphate buffer, because a pH that is too acidic or alkaline can cause the color of the nucleus and cytoplasm of cells to become unclear. This study aims to determine the effect of differences in phosphate buffer pH on the quality of Giemsa staining in leukocyte differential count examinations. This study used a quasi-experimental design with a quantitative approach and was conducted in January 2025 at the Medical Laboratory Technology Laboratory of the Muhammadiyah University of Kudus. The independent variable was the pH of the phosphate buffer with variations of pH 4, 7, and 8, while the dependent variable was the quality of Giemsa staining on leukocyte differential counts. The research sample consisted of 9 final year students selected using random sampling technique, with each sample receiving three different phosphate buffer pH treatments. Data analysis was performed using the Kruskal-Wallis test because the data were not normally distributed and showed significant differences between pH groups. Further Mann-Whitney tests showed significant differences between pH 7 and pH 8 groups. The results indicate that variations in phosphate buffer pH affect the quality of Giemsa staining and leukocyte count accuracy.
References
- Arianda, D. (2019). Buku Saku Analis Kesehatan Revisi Ke-7.
- Asghar, R., Kumar, S., Shaukat, A., & Id, P. H. (2024). Classification of white blood cells ( leucocytes ) from blood smear imagery using machine and deep learning models : A global scoping review. 1–25. https://doi.org/10.1371/journal.pone.0292026
- Dewi, F. R. (2024). Perbedaan Intensitas Nyeri Sebelum dan Sesudah Diberikan Massage Effleurage pada Ibu Bersalin kala 1 Fase Aktif di Rumah Sakit Pertamina Balikpapan. Repository. http://repository2.unw.ac.id/id/eprint/4106
- Ella Agustina, S. A. (2025). Perbandingan Jumlah Leukosit, Limfosit, Monosit, Neutrofil Pada Pasien Demam Tifoid Dan Demam Dengue. Jurnal Medika, 10(1), 23–28. https://doi.org/10.53861/jmed.v10i1.570
- Fauzi, A., Novilla, A., Ningrum, N. R., & Herawati, I. (2024). Perbandingan Kadar Hemoglobin Menggunakan POCT (Point Care Of Testing) dengan Alat Hematology Analyzer Pada Pasien Normal dan Anemia. Jurnal Ilmiah Kesehatan, 16(2), 386–394. https://doi.org/10.37012/jik.v16i2.2329
- Indriani, M. (2017). Pengaruh Konsentrasi pH Buffer Giemsa terhadap Morfologi Leukosit pada Preparat Sumsum Tulang. Pengaruh Konsentrasi Ph Buffer Giemsa Terhadap Morfologi Leukosit Pada Preparat Sumsung Tulang., 167–186. http://repository.unimus.ac.id/id/eprint/1214
- Jackson, S., Grabis, D., Manav, C., Louis, S., & Kgaa, M. (2018). Giemsa : The Universal Diagnostic Stain. Sigma-Aldrich, 33(8), 2671.
- Muflihah, A. I., Destiawan, R. A., Wijaya, A. F., Widia, L. Y., sufi, Q. N., Azizah, L. C. N., & Makki, A. A. (2022). The Effect of Differences Time On The Macroscopic Picture Of Giemsa Staining Using Aquades Diluent-Ahdiah Imroatul Muflihah The Effect of Differences Time On The Macroscopic Picture Of Giemsa Staining Using Aquades Diluent under a Creative Commons Attribu. Jurnal Eduhealt, 13(02), 1217–1221. http://ejournal.seaninstitute.or.id/index.php/healt
- Muhammad Fahmi Aminuddin, Amelia Soda, M. T. M. (2025). Gambaran Jumlah dan Jenis Leukosit pada pasien Rumah Sakit Umum Daerah Abdul Wahab Sjahranie Samarinda. Jurnal Teknologi Laboratorium Medik Borneo, 5(1), 47–52. https://doi.org/10.35728/jutelmo.v5i1.1866
- Museyaroh, M. H. N. dan L. H. E. (2025). Health Dynamics Analysis of the Leukocyte Profile for Peripheral Blood Smear Stained with Diff-Count Based on Fixation Time Variation Health Dynamics. 2(2), 47–55.
- Mustafa, Tri Dyah Astuti, A. B. W. (2024). Perbedaan Morfologi Neutrofil dan Limfosit pada Apusan Darah Tepi Metode Giemsa menggunakan Buffer Fosfat, Aquadest dan NaCl Fisiologis. 5(September), 7837–7842.
- Nisa, A. Z., Hidayah, N., & Kurnia, S. D. (2025). Pengaruh Suhu Dan Waktu Penyimpanan Darah EDTA Terhadap Hasil Jumlah Trombosit Dengan Metode Otomatis The Effect of Temperature and Storage Time of EDTA Blood on Platelet Count Results Using Automated Method. Jurnal Analis Kesehatan, 14(I), 25–32.
- Oktiyani, N., Muhlisin, A., Roebiakto, E., Norsiah, W., & Mahpolah, M. (2022). Utilization of Alternative Buffer Solutions for Staining Thin Blood smears by the Giemsa, Wright stain and Romanowsky method. Tropical Health and Medical Research, 5(1), 34–45. https://doi.org/10.35916/thmr.v4i1.76
- Putri, R. K. (2024). Perbedaan Hasil Pewarnaan Eritrosit dan Leukosit pada Sediaan Apus Darah Tepi menggunakan Giemsa 10% dan Giemsa 20%. Library Poltekkes Kemenkes Yogyakarta. https://poltekkesjogja.ac.id/
- Rizki Anandra dan Dwi Purbayanti. (2025). Barigas Medical and Health Science Journal Volume 01, Issue 02, Page 24 - 29. 01(02), 24–29.
- Satya Darmayani, Fonnie E. Hasan, D. E. A. (2016). PERBEDAAN HASIL PEMERIKSAAN JUMLAH LEUKOSIT ANTARA METODE MANUAL IMPROVED NEUBAUER DENGAN METODE AUTOMATIC HEMATOLOGY ANALYZER. 2(2002).
- Shaubilla, A. (2023). Gambaran Hasil Pewarnaan Sediaan Apus Darah Tepi dengan Giemsa 10% Menggunakan Aquadest dan Buffer Phosphate pH 7,2. Gastronomía Ecuatoriana y Turismo Local., 1(69), 5–24.
- Subyadinata, J., Tlp, N., Garut, F., & Barat, J. (2024). MENGGUNAKAN PEWARNA GIEMSA TANPA PENGENCERAN SEKOLAH TINGGI ILMU KESEHATAN KARSA HUSADA GARUT PROGRAM STUDI D-III ANALIS KESEHATAN Pewarnaan Sediaan Apus Darah Tepi ( SADT ) Menggunakan Pewarna Giemsa Tanpa Pengenceran Staining of Peripheral Blood Smear Preparations ( SADT ) Using Giemsa stain without Dilution. 22.
- Wardani, Y. P. (2025). Comparative Analysis of Erythrocyte , Leukocyte , and Platelet Indices through Examinations Using Sysmex XN-3000 and Yumizen H2500 in Clinical Practice. 06(1), 31–37. https://doi.org/10.20473/cimrj.v6i1.65391
- Yati, M., Muhlisin, A., Muntaha, A., & Roebiakto, E. (2023). Kualitas Pewarnaan Sediaan Apusan Darah Metode Giemsa Menggunakan Alternatif Pewarna Buah Naga Pengencer Air Mineral. Jurnal Karya Generasi Sehat, 1(1). https://doi.org/10.31964/jkgs.v1i1.66