SEQUENCE APPLICATION OF BRAIN MRI WITH ORTHODONTIC BRACKET

Aryadiva Prayoga, Hermien Nugraheni, Diyah Fatmasari

Abstract


Magnetic Resonance Imaging (MRI) examination of the brain at high resolution will be able to detect abnormalities in the brain that are not detected before. The MRI machine is equipped with a very strong magnetic force, therefore metal objects can interfere with the workings of the machine . Some patients, there may be a magnet in the body unnoticed, for example: orthodontic bracket. The purpose of this study was to analyze the effectiveness of sequences to reduce metal artifacts due to the installation of the Orthodontic Bracket. This type of research is a quantitative analytic with a quasi-experimental research design. The research design used was a one group pretest-posttest design to determine the optimization of the application of the Slice Encoding Metal Artifact Correction (SEMAC) and View Angle Tilting (VAT) sequences on Brain MRI with Orthodontic Bracket. The results showed that the SEMAC sequence combined with T2 TSE was able to reduce metal artifacts well. VAT sequences combined with T2 TSE were able to reduce metal artifacts quite well. A more optimal sequence to reduce metal artifacts is T2 TSE SEMAC, where the sequence is able to reveal thin structures that are not visible in the T2 TSE or T2 TSE VAT sequences. 

Keywords


Brain MR; Orthodontic Bracket

Full Text:

PDF

References


Bachschmidt T, Lipps F, Ph D, Nittka M. syngo WARP – Metal Artifact Reduction Techniques in Magnetic Resonance Imaging. Magnetom Flash. 2012;(2):24-25.

Beau A, Bossard D, Gebeile-Chauty S. Magnetic resonance imaging artefacts and fixed orthodontic attachments. Eur J Orthod. 2015;37(1):105-110. doi:10.1093/ejo/cju020

Bennett, L.H, Wang, P.S. MJD. Artifacts in magnetic resonance imaging from metals. Polish J Radiol. 1996;80:93-106. doi:10.12659/PJR.892628

Brown, et.al. MRI Basic Principles and Applications. Vol 39.; 2003.

Chen CA, Chen W, Goodman SB, et al. New MR imaging methods for metallic implants in the knee: Artifact correction and clinical impact. J Magn Reson Imaging. 2011;33(5):1121-1127. doi:10.1002/jmri.22534

Edmund JM, Nyholm T. A review of substitute CT generation for MRI-only radiation therapy. Radiat Oncol. 2017;12(1):1-15. doi:10.1186/s13014-016-0747-y

Ellis H. Clinical Anatomy.; 2006. doi:10.1002/(SICI)10982353(1996)9:1<61::AID-CA14>3.0.CO;2-8

Faller A, Schuenke M. The Human Body - An Introduction to Structure and Function. Vol 53.; 2004. doi:10.1017/CBO9781107415324.004

Filli L, Jud L, Luechinger R, et al. Material-dependent implant artifact reduction using SEMAC-VAT and MAVRIC: A prospective MRI phantom study. Invest Radiol. 2017;52(6):381-387. doi:10.1097/RLI.0000000000000351

Friedrich B, Wostrack M, Ringel F, et al. Novel Metal Artifact Reduction Techniques with Use of Slice-Encoding Metal Artifact Correction and View-Angle Tilting MR Imaging for Improved Visualization of Brain Tissue near Intracranial Aneurysm Clips. Clin Neuroradiol. 2016;26(1):31-37. doi:10.1007/s00062-014-0324-4

Haris Khan. Orthodontic Bracket Selection, Placement and Debodning. JADA, Vol. 138 http://jada.ada.org April 2007.

Braces Straighter teeth can improve oral health. Am Dent Assoc. 2007;30(9):504-505. doi:10.1016/S0096-6347(44)90006-2

Jawad Z, Bates C, Hodge T. Who needs orthodontic treatment? Who gets it? and who wants it? Br Dent J. 2015;218(3):99-103. doi:10.1038/sj.bdj.2015.51

Jungmann PM, Ganter C, Schaeffeler CJ, et al. View-angle tilting and slice-encoding metal artifact correction for artifact reduction in MRI: Experimental sequence optimization for orthopaedic tumor endoprostheses and clinical application. PLoS One. 2015;10(4):1-18. doi:10.1371/journal.pone.0124922

Liney G. MRI in Clinical Practice. Vol 39.; 2006.

Mamourian, Alexander C. . Practical Mr Physics.; 2010.

Moeller TB. MRI Parameters and Positioning.; 2010.

Moore, Keith L Clinically Oriented Anatomy.; 2014. doi:10.1016/B978-0-7020-4312-3.00031-3

Noelia A, Itati GL, Matilde S. The need for orthodontic treatment according to severity of malocclusion in adult patients. 2015.

Ontario HQ. The Appropriate Use of Neuroimaging in the Diagnostic Work-Up of Dementia: OHTAC Recommendation. 2014;14(1).

Poorsattar-Bejeh Mir A, Rahmati-Kamel M. Should the orthodontic brackets always be removed prior to magnetic resonance imaging (MRI)? J Oral Biol Craniofacial Res. 2016;6(2):142-152. doi:10.1016/j.jobcr.2015.08.007

Reichert M, Ai T, Morelli JN, Nittka M, Attenberger U, Runge VM. 2015. Metal Artifact Reduction in MR Imaging at Both 1,5 T and 3T Using Slice-Encoding or Metal Artifact Correction and View Angle Tilting.

Reimer P. Clinical MR Imaging.; 2010. doi:10.1007/978-3-540-74504-4

Simanjuntak, Josepa ND. Studi Analisis Echo Train Length Dalam K- Space Serta Pengaruhnya Terhadap Kualitas Citra Pembobotan T2 Fse Pada MRI 1,5 T. 2014;17(1):7-12.

Smith TB, Nayak KS. MRI artifacts and correction strategies. Imaging Med. 2010;2(4):445-457doi:10.2217/iim.10.33

Suryanegara, Rina J Memperbaiki Dan Memperindah Posisi Gigi Anak.; 2000.

Talbot BS, Weinberg EP. MR Imaging with Metal-suppression Sequences for Evaluation of Total Joint Arthroplasty. RadioGraphics. 2016;36(1):209-225. doi:10.1148/rg.2016150075

Vernooij MW, Ikram MA, Tanghe HL, et al. Incidental Findings on Brain MRI in the General Population. N Engl J Med. 2007;357(18):1821-1828. doi:10.1056/NEJMoa070972

Wellman F. Evaluation of methods for MR imaging near metallic hip prostheses. 2011:37. doi:10.1155/2012/815870

Westbrook, Catherine W. Handbook of MRI Technique 4th Edition. Vol 136.; 2014.

Westbrook, Catherine - Handbook Of Mri Technique 2nd edition. 2014.

Westbrook C, Talbot J, Roth C. MRI: In Practice.; 2011.

Westbrook, Catherine W. MRI at a Glance. Vol 196.; 2002. doi:10.2214/AJR.10.6192

Woodward P. MRI for Technologist. Mc.Graw-Hill Medical; 2000.




DOI: https://doi.org/10.31983/jrk.v9i1.5690

Article Metrics

Abstract view : 630
Download PDF : 410

Refbacks

  • There are currently no refbacks.




Copyright (c) 2020 Jurnal Riset Kesehatan

INDEXING

Logo Google Schoolar
Logo Sinta
Logo DOAJ
Logo Crossref
Logo Garuda
Logo Dimensions
RECOMMENDED TOOLS
Turnitin Logo
EndNote Logo
Mendeley Logo
Keep in touch with us!
Get notified
Logo Poltekkes Semarang Logo JRK
JURNAL
RISET
KESEHATAN

Mailing Address:

Jalan Tirto Agung, Pedalangan, Kec. Banyumanik, Kota Semarang, Jawa Tengah - 50268, Indonesia

Commitment to quality

Double-blind peer review. Immediate open access. Authors retain copyright. No author fees. Published biannually.

 
CC Brands CC BY Brands CC SA Brands

Journal Riset Kesehatan (JRK), its website, and the articles published therein are licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.

WGA