OPTIMALIZATION OF WINDOW WIDTH AND WINDOW LEVEL ON LUNG WINDOW FOR ANATOMIC INFORMATION CT SCAN THORAX OF LUNG TUMORS CASE IN RSUD TUGUREJO PROVINCE OF CENTRAL JAVA

Anggraini Dwi S, Rasyid Rasyid, Darmini Darmini

Abstract


Background: Settings for Window Width and Window Levels used in CT Scan Thorax tumor cases vary. On Seimens 128 Slice plane there are standard settings for lung window thorax is with Window Width 2200 HU and Window Level -200 HU while according to window width theory is 1000- 2000 HU value range and window level -200--800 HU. The purpose of this research is to know the difference of variation setting Window Width and Window Level on Lung Window and Window Width and Window Level optimum in producing anatomical information CT scan thoraks in case of lung tumor.

Method: The type of research conducted in the writing of this final task is quantitative research using experimental approach. Data were collected on 5 patients suspected of lung tumor, then variation of setting window width and window level. The result of variation of window width and window level setting was then evaluated by 2 observers to obtain anatomical information of CT Scan Thorax in lung tumor case then analyzed by using Friedman Test different from spss version 16.0.

Result: The result of the research resulted the difference of Window Width and Window Level was assessed from p value <α (0.05). the value of significance p value 0.001 which means there is a difference. Highest mean mean value with value 8.25 in window width 1800 HU and window level -200 HU. The use of the most optimal setting variation is the Window Width 1800 HU and Window Level -200 HU because it can provide anatomical image information of CT Scan Thoraks optimal lung tumor cases where the anatomy of the pulmonary, broncus, trachea, aortic mass, pulmonary and chest lung par clearly visible and bordered on axial pieces.


Keywords


CT Scan Thorax; Lung Tumors; Window Width and Window Level

Full Text:

PDF

References


Ballinger, P. W. 1999. Merill’s Atlas of Radiographic Position and Radiologic Procedures, Volume One, The CV. Mosby, Co. London

Bontrager, Kenneth L. 2001. Textbook of Positioning and Related Anatomy, Fifth Edition. CV. Mosby Company, St. Louis.

Bushberg, J. T. 2003. The Essential Phisics of Medical Imaging, Second Edition, Lippincot Williams & Wilkins, Philadelphia.

Bushong, C, Stewart. 2001. Computed Tomography, Mc Graw Hill Company, New York.

Even Ronald G, fred A. Mettler. 1993, “ Nasional CT Use and Radiation Xposure : United States 1983, American Roengent Ray Society,” available online : www.ajronline.org/cgi/content/abstract/144/5/1077

Fencis Heins, Wolfgang Dauber. 2000. “Pocket atlas of Human anatomy : Base On International Nomenclatur,” Fourth Edition, Thieme Stuugart, New York

Jaengsri N, MSc. 2004. Protocol CT Technique, Radiology Departement of Taleshin Hospital, Bangkok Thailand.

Karabulut Nevzat, Macit Ariyurek. 2006. Low dose CT : Practices and strategis of radiologist in university hospitals, Turkish Society of Radiology, www.dirjournal.org/pdf/pdf DJR-54 pdf

Neseth, Roland. 2000. Prosedure and Documentation for CT and MRI. Mc Graw-Hill Medical Publishing Division, Kansas.

Pearce, E. C. 1999. Anatomi dan Fisiologi untuk Paramedis, Gramedia Pustaka Utama Jakarta.

Philip W ballinger. Eugene C. Frank. 1999. Merril’s Atlas of Radiographic Positions and Radiologic Procedures Volume Three, Mosby Inc, St. Louis, Missouri.

Platten, David. 2003. Multi-slice Helical Ct physic and technology. www.impactscan.com

Rasad, Sjahriar, dkk. 2000. Radiologi Diagnostic, Edisi Kedua. Balai Penerbit FKUI, Jakarta.

Seeram E. 2001. Computed Tomography: physical principles, clinical applications, and quality control, Second edition, WB Saunders Company, Philadelphia.

Sloane E. 2003. Anatomi dan Fisiologi untuk Pemula. EGC. Jakarta.

Tortorici, M. 1999. Concepts in Medical Radiographic Imaging : Circutry, Exspose & Quality Control, W. B. Saunders Company, Philadelphia, Pennsylvana.




DOI: https://doi.org/10.31983/jimed.v4i2.3993

Article Metrics

Abstract view : 883
Download PDF : 2460

Refbacks

  • There are currently no refbacks.



Creative Commons License  Statcounter Global Stats - Browser, OS, Search Engine including Mobile  Usage Share          Dimensions AI | The most advanced scientific research database

             
JURNAL IMEJING DIAGNOSTIK by http://ejournal.poltekkes-smg.ac.id/ojs/index.php/jimed is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.

View My Stats